{"id":1005,"date":"2026-02-04T07:51:08","date_gmt":"2026-02-04T07:51:08","guid":{"rendered":"https:\/\/lmh.kz\/?page_id=1005"},"modified":"2026-02-04T07:51:09","modified_gmt":"2026-02-04T07:51:09","slug":"bd-bactec-fx40","status":"publish","type":"page","link":"https:\/\/lmh.kz\/en\/bd-bactec-fx40\/","title":{"rendered":"BD Bactec FX40"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"568\" src=\"https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-1024x568.png\" alt=\"\" class=\"wp-image-1003\" style=\"aspect-ratio:1.8029172697917826;width:393px;height:auto\" srcset=\"https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-1024x568.png 1024w, https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-300x167.png 300w, https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-768x426.png 768w, https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40.png 1317w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p><strong>BD BACTEC FX40 Bacteriological Analyzer<\/strong><\/p>\n\n\n\n<p><strong>Registration Certificate in RK:<\/strong> RK-MT-7 No. 014761<\/p>\n\n\n\n<p><strong>Registration Date:<\/strong> September 11, 2015 <\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">System Overview<\/h3>\n\n\n\n<p>The <strong>BD BACTEC FX40<\/strong> is an automated system designed for the rapid detection of bacteria and fungi in clinical specimens<sup><\/sup><sup><\/sup><sup><\/sup><sup><\/sup>.+1<\/p>\n\n\n\n<p><strong>Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Modular Design:<\/strong> Offers installation flexibility to meet specific laboratory requirements.<\/li>\n\n\n\n<li><strong>User Interface:<\/strong> Features a color touch-screen graphic display for ease of use.<\/li>\n\n\n\n<li><strong>Real-time Monitoring:<\/strong> Internal sensors immediately detect the placement or removal of vials.+1<\/li>\n\n\n\n<li><strong>Versatility:<\/strong> Supports simultaneous processing of bacterial, fungal, and mycobacterial cultures using various media types.<\/li>\n\n\n\n<li><strong>Connectivity:<\/strong> Can be integrated with a compatible Laboratory Information System (LIS) or the BD EpiCenter data management system.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Method Principles<\/h3>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Metabolism:<\/strong> Microorganisms in the culture vials consume nutrients and release carbon dioxide ($CO_2$) into the medium.<\/li>\n\n\n\n<li><strong>Reaction:<\/strong> A dye in the sensor at the bottom of the vial reacts with the $CO_2$.<\/li>\n\n\n\n<li><strong>Detection:<\/strong> This reaction modulates the light absorbed by the detector&#8217;s fluorescent material.<\/li>\n\n\n\n<li><strong>Measurement:<\/strong> A photodetector at each station measures fluorescence levels every ten minutes.<\/li>\n\n\n\n<li><strong>Alerts:<\/strong> When a &#8220;positive&#8221; result is identified based on pre-programmed parameters, the system triggers an indicator light, an audible alarm, and displays the culture on the tablet.<\/li>\n\n\n\n<li><strong>Confirmation:<\/strong> Laboratory technologists then remove positive vials for subculturing and identification.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Media Overview<\/h3>\n\n\n\n<p>The system supports several specialized media types:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Medium Type<\/strong><\/td><td><strong>Catalog No.<\/strong><\/td><td><strong>Recommended Volume (Optimal)<\/strong><\/td><td><strong>Key Features<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Standard\/10 Aerobic \/F<\/strong><\/td><td>442260<\/td><td>3.0 \u2013 10.0 ml (8.0 \u2013 10.0 ml)<\/td><td>General aerobic testing<sup><\/sup>.<\/td><\/tr><tr><td><strong>Plus Aerobic \/F<\/strong><\/td><td>442192<\/td><td>3.0 \u2013 10.0 ml (8.0 \u2013 10.0 ml)<\/td><td>Contains resins for antibiotic neutralization<sup><\/sup>.<\/td><\/tr><tr><td><strong>Standard Anaerobic \/F<\/strong><\/td><td>442191<\/td><td>3.0 \u2013 7.0 ml (5.0 \u2013 7.0 ml)<\/td><td>General anaerobic testing<sup><\/sup>.<\/td><\/tr><tr><td><strong>Peds Plus \/F<\/strong><\/td><td>442194<\/td><td>0.5 \u2013 5.0 ml (1.0 \u2013 3.0 ml)<\/td><td>Optimized for pediatric\/low-volume samples; includes resins<sup><\/sup>.<\/td><\/tr><tr><td><strong>Plus Anaerobic \/F<\/strong><\/td><td>442193<\/td><td>3.0 \u2013 10.0 ml (8.0 \u2013 10.0 ml)<\/td><td>Anaerobic medium with antibiotic-neutralizing resins<sup><\/sup>.<\/td><\/tr><tr><td><strong>Lytic\/10 Anaerobic \/F<\/strong><\/td><td>442265<\/td><td>3.0 \u2013 10.0 ml (8.0 \u2013 10.0 ml)<\/td><td>Contains saponin to lyse blood cells and release phagocytized organisms<sup><\/sup>.<\/td><\/tr><tr><td><strong>Myco\/F Lytic<\/strong><\/td><td>442003<\/td><td>1.0 \u2013 5.0 ml (3.0 \u2013 5.0 ml)<\/td><td>Specialized for yeast, fungi, and mycobacteria<sup><\/sup><sup><\/sup><sup><\/sup><sup><\/sup>.+1<\/td><\/tr><tr><td><strong>Mycosis IC \/F<\/strong><\/td><td>442026\/06<\/td><td>3.0 \u2013 10.0 ml<\/td><td>Selective medium for fungal recovery<sup><\/sup>.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"930\" height=\"465\" src=\"https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-\u0444\u043b\u0430\u043a\u043e\u043d\u044b.jpg\" alt=\"\" class=\"wp-image-1004\" srcset=\"https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-\u0444\u043b\u0430\u043a\u043e\u043d\u044b.jpg 930w, https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-\u0444\u043b\u0430\u043a\u043e\u043d\u044b-300x150.jpg 300w, https:\/\/lmh.kz\/wp-content\/uploads\/2026\/02\/fx40-\u0444\u043b\u0430\u043a\u043e\u043d\u044b-768x384.jpg 768w\" sizes=\"auto, (max-width: 930px) 100vw, 930px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Technical Specifications <sup><\/sup><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Specification<\/strong><\/td><td><strong>Individual Instrument<\/strong><\/td><td><strong>With Rack<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Height<\/strong><\/td><td>39.1 cm<\/td><td>77.5 cm<\/td><\/tr><tr><td><strong>Width<\/strong><\/td><td>67.5 cm<\/td><td>67.5 cm<\/td><\/tr><tr><td><strong>Depth<\/strong><\/td><td>58.5 cm<\/td><td>58.5 cm<\/td><\/tr><tr><td><strong>Weight (Empty\/Full)<\/strong><\/td><td>31.8 kg \/ 38.0 kg<\/td><td>64.6 kg \/ 76.9 kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Operating Requirements:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Voltage:<\/strong> 100 \u2013 240 VAC \u00b1 10% (50 \u2013 60 Hz).<\/li>\n\n\n\n<li><strong>Operating Temperature:<\/strong> 18.0\u00b0C to 30.0\u00b0C.<\/li>\n\n\n\n<li><strong>Humidity:<\/strong> 25% to 80% non-condensing.<\/li>\n\n\n\n<li><strong>Placement:<\/strong> Level surface, away from direct sunlight, heat sources, or excessive dust.<\/li>\n\n\n\n<li><strong>Noise Level:<\/strong> \u2264 55 dBA at 1 meter.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>Note:<\/strong> This information is an overview. A full electronic copy of the User Manual is available upon request<sup><\/sup>.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n","protected":false},"excerpt":{"rendered":"<p>BD BACTEC FX40 Bacteriological Analyzer Registration Certificate in RK: RK-MT-7 No. 014761 Registration Date: September 11, 2015 System Overview The BD BACTEC FX40 is an automated system designed for the rapid detection of bacteria and fungi in clinical specimens.+1 Key Features: Method Principles Media Overview The system supports several specialized [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_locale":"en_US","_original_post":"https:\/\/lmh.kz\/?page_id=1002","footnotes":""},"class_list":["post-1005","page","type-page","status-publish","hentry","en-US"],"_links":{"self":[{"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/pages\/1005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/comments?post=1005"}],"version-history":[{"count":1,"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/pages\/1005\/revisions"}],"predecessor-version":[{"id":1009,"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/pages\/1005\/revisions\/1009"}],"wp:attachment":[{"href":"https:\/\/lmh.kz\/wp-json\/wp\/v2\/media?parent=1005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}